Africa Flying

Combustor Facilities - NASA

Combustor Facilities – NASA


Combustion studies are conducted in this two-test position facility specifically in support of the NOx-reduction research for the High Speed Research program and the Advanced Subsonic Technology program. CE-5B-1 is large enough to test sector arrangements of injector elements to include interactions of the elements and single larger elements. The facility receives filtered combustion air from the 450-psig system. The air is heated in a 1,100°F non-vitiated heater at flows up to 20 lb/s, which can be valved to either test stand. The airflow passes through the test section, is water spray quenched, and is then discharged to the altitude exhaust system or the atmospheric exhaust system. The facility preheater consists of a heat exchanger fired by four J-47 burner cans using natural gas for a fuel and the 40-psig combustion air. The research hardware uses ASTM Jet-A, JP-5, or JP-8 as a fuel. 

CE-5B-1 Special Features

In addition to inlet and exit rakes and standard instrumentation, water-cooled gas sampling rakes are in the downstream section. Particulate measurements are taken at the exit of the combustion section. Optical accessibility of the combustor section allows never-before-possible nonintrusive laser-based diagnostics of the reacting and non-reacting flowfield. These include such techniques as planar laser-induced fluorescence (PLIF) imaging, Planar Mie scattering, Phase/Doppler particle analysis (PDPA), focused Schlieren imaging, and light sheet photography. Both rigs share the gas analysis, particulate analysis, and diagnostics equipment. 

CE-5B Facility Capabilities (typical of both rigs)

Parameter
Operating Value

Inlet Air Supply Pressure
450 psig

Inlet Air Temperature
100°F, preheated to 350-1,350°F

Inlet Airflow Stand 1 Stand 2 
20 lb/s (available) 0.5 to 12.0 pps 0.5 to 5.0 pps

Exhaust
Atm or 20-26 in. Hg

Rig Pressure Without Windows Stand 1 Stand 2
275 psig 400 psig

Rig Pressure With Windows Stand 1 Stand 2
250 psig 275 psig

Rig Fuel (JP-8) Flow
7 gpm @ 400-900 psig (three legs per stand)

Window Cooling GN2 (4 legs)
0.125 to 0.5 pps (each leg) 

Cooling Water
150 gpm @ 460 psig 250 gpm @ 395 psig 50 gpm @ 350 psig 15 gpm @ 55 psig

CE-5B-1 System Instrumentation

System
Number and Type

ESP
96 Ports of + 500 PSID Barometric Ref

Escort
240 Channels 154 Available to the Customer

Thermocouples
156 Type K 24 Type B 12 Type W 524 Type R

Gas Analyzers
HC – 1,000 ppm 1% & 5% CO – 2,000 ppm 5% CO2 – 5%, 10%, 20% O2 – 25% NO – 100 ppm, 1,000 ppm 1% NOx –

Laser
PLIF, Raman

CE-5B-2 is one of the two test stands in the CE-5B facility. It can be configured to study lean-premixed-prevaporized (LPP) and lean-direct-injection (LDI) concepts for developing a low-NOx combustor for high-speed research and advanced subsonic applications. The non-windowed combustion flame tube can use a 3-inch square cross section or a 3-inch-diameter round section and has six ports available for gas sampling probes. The windowed combustion flame tube takes advantage of the flat walls on a 3-inch square cross section to install optical windows for non-intrusive measurements. Tests are conducted with combustion air inlet pressure ranging from 10 to 15 atmospheres with preheater and exhaust conditions described for CE-5B-1. 

CE-5B-2 Special Features 

The same laser-based non-intrusive diagnostics of reacting and non-reacting flowfields described for test position CE-5B-1 are available to this test section. A typical data acquisition system is used for both test positions in CE-5B. In addition, most of the optical diagnostic instruments have their own data acquisition systems.

CE-5B Facility Capabilities (typical of both rigs)

Parameter
Operating Value

Inlet Air Supply Pressure
450 psig

Inlet Air Temperature
100°F, preheated to 350-1,350°F

Inlet Airflow Stand 1 Stand 2 
20 lb/s (available) 0.5 to 12.0 pps 0.5 to 5.0 pps

Exhaust
Atm or 20-26 in. Hg

Rig Pressure Without Windows Stand 1 Stand 2
275 psig 400 psig

Rig Pressure With Windows Stand 1 Stand 2
250 psig 275 psig

Rig Fuel (JP-8) Flow
7 gpm @ 400-900 psig (three legs per stand)

Window Cooling GN2 (4 legs)
0.125 to 0.5 pps (each leg) 

Cooling Water
150 gpm @ 460 psig 250 gpm @ 395 psig 50 gpm @ 350 psig 15 gpm @ 55 psig

CE-5B-2 System Instrumentation

System
Number and Type

ESP
96 Ports of + 500 PSID Barometric Ref

Escort
240 Channels 154 Available to the Customer

Thermocouples
148 Type K 24 Type B 48 Type R

Gas Analyzers
HC – 1,000 ppm 1% & 5% CO – 2,000 ppm 5% CO2 – 5%, 10%, 20% O2 – 25% NO – 100 ppm, 1,000 ppm 1% NOx –

Laser
PLIF, Raman

Test Cell CE-13 Combustion and Dynamics Facility (CDF) is used to investigate ways to reduce NOx and particulate emissions from air-breathing aircraft engines. This low-pressure (1-5 atm) facility is used to study fuel-air injection schemes and how they affect fluid mixing, emissions, dynamics, and flame stability. Jet-A fuel is the primary fuel, but candidate alternate jet fuels and their effects are also studied. Standard measurements consist of major species and dynamic pressures. Some optical measurements available are high-speed video, standard and time-resolved 2D PIV, planar laser induced fluorescence (PLIF), and chemiluminescence imaging.

CE-13C Special Features

Research hardware is designed to flow vertically downwards. Preheated air is fed to the inlet air stream conditioner and then to the fuel injector. Fuel at room temperature is fed separately to the injector. The mixed hot air and fuel mixture moves to the combustor where combustion can be observed via customized windows. The products of combustion flow through an emission sampling ring and choke nozzle/straight outlet pipe. The fuel system consists of a 25-gallon fuel tank, a pump, and a GN2 purge. A separate laser room operates various class 3B and 4 lasers (UV, Vis, NIR) to characterize fuel injection, combustor flow, and measure combustion species.

CE-13C Facility Capabilities

Parameter
Operating Value

Inlet Air Pressure
Ambient to 75-psia

Inlet Air Temperature
Ambient to 1,000°F

Inlet Airflow
0.0 – 1.0 pps

Jet Fuel Supply
CKT 1 6.9-140 pph @ 1,000-psig CKT 2 1 – 13.1 pph @ 1,000-psig 

Exhaust
Atmospheric

Peripheral H2O Cooling
54-gpm @ 100-pisg

Quench Cooling
11-gpm @ 500-psig

CE-13C System Instrumentation

System
Number and Type

Labview
64 voltage/current channels 32 temperature channels 10 voltage/current channels available to the customer 30 temperature channels available to customer

Optical and Laser
PLIF, Raman, PIV, droplet sizing, chemiluminescence, temperature, time-resolved imaging

Gas Analyzers
CO – 1,000 ppm, 5,000 ppm CO2 – 5%, 15% O2 – 25% NO – 100 ppm, 1,000 ppm NOx – 100 ppm, 1,000 ppm HC –  100 ppm, 1,000 ppm 

The SE-5 High-Pressure Combustion Diagnostics (HPCD) laboratory is a gas- and liquid-fueled high-pressure flame tube facility with single-element fuel injection burners and emission sampling ports for advanced diagnostics development and national standard calibrations. The facility provides large-aperture optical access to the primary reaction zone (flame holding) through four UV-grade fused silica optical windows (44-mm-thick by 85-mm clear apertures located around the periphery) enabling non-intrusive optical diagnostics such as laser Raman spectroscopy or high-speed imaging to measure chemical species and temperature. The HPCD rig can operate at sustained pressures up to 30 atm (or 60 atm with limited flow rate) with a variety of gaseous fuels, liquid jet fuels, and oxidizers, including hydrogen, methane, oxygen-argon, and pure oxygen. The innovative microtube array burner or micro-radial-entry counter-swirl (MRX) burner is mounted inside the air-cooled high-temperature liner casing within the rig. The burner was designed to provide a uniform combustion product zone downstream of the flame for calibrating the laser diagnostic system. The facility is also used for bench-mark tests of emission gas and particulate matters (PM) sampling. The data from the HPCD rig enables the validation of numerical codes such as powered by advanced CFD that simulate gas turbine combustors. All aspects of the facility operation, including startup, shutdown, and automatic safety shutdowns, are controlled and monitored via an icon-based touch-screen software system and a most-updated programmable logic controller (PLC) in conjunction with a precision DEWETRON data acquisition system. The HPCD rig can also provide a pressure vessel for prototype thermal or combustion hardware of a customer’s choice.

SE-5 Special Features

The facility is unique because it is the only continuous-flow, hydrogen-capable 60-atm rig in the world with optical access. It will provide researchers with new insights into flame conditions that simulate the environment inside the ultra-high pressure-ratio combustion chambers of tomorrow’s advanced aircraft engines.

SE-5 Facility Capabilities

Parameter
Operating Value

Cooling Capacity
4,000,000 BTU/hr

Equivalence Ratio Variance
0.2 (fuel very lean) – 4 (fuel rich)

Fuel Flow Rate
Limited by cooling capacity, e.g., 2 GPH of n-heptane

Operating Pressure
30 atm nominal, 60 atm max

Cooling Airflow
0.25 lbm/s max

Quenching Airflow
0.20 lbm/s max 

SE-5 System Instrumentation and Diagnostics

System
Number and Type

Pressure Transducers and Thermocouples
Custom

DEWETRON DAQ
Custom

Emission Gas Sampling (Exhaust)
NO, NOx, SOx, O2, CO, CO2

Particulates Sampling (Exhaust)
Mass (TSI), counter (TSI), In-line sensor (GRC in-house)

Laser Raman Spectroscopy (In Flame)
Custom

In-situ Soot Detection
Extinction measurements

The Particulate Aerosol Laboratory (PAL) studies aerosols at simulated upper atmospheric conditions with altitudes up to 55,000 feet at -135°F. Altitude chamber environment and burner settings are individually controlled, creating a multitude of test parameters and a dynamic testing environment. The PAL facility is designed around a small-scale jet exhaust nozzle and altitude chamber and takes full advantage of its reduced size for screening of various alternative fuels, additives, and other combustion concepts. This makes PAL the ideal facility for validating the advancement of such research to the next phase. 

Combustion fuel operation capabilities include alternative fuel additive mixing in real-time mode with switching between a baseline fuel and an alternative fuel while maintaining a continuous combustion flame. Heated bypass air is available with optional external burner and associated piping heating up to 1,000°F. Additionally, PAL is enhancing its cloud simulation capability with real-time atmospheric water vapor content readings and on-demand direct liquid injector vaporizers for high purity 100% fluid vaporization.

SE-11 Special Features 

Particulate emission sample extraction taking at burner rear section. Chamber equipped with windows and fused silica lenses providing optical access for non-intrusive optical diagnostic Mie scattering and color video imaging. Particulate size and number density measurements are accomplished with absorption measurements and forward, back, and side scattering. Video capability of both burner flame and altitude chamber contrails. Optical measurement plane location relative to the chamber nozzle exit is adjustable.

SE-11 Facility Capabilities

Parameter
Operating Value

Burner Fuel Flow Rate
.2 – 9.9 ml/min various liquid fuels

Burner Air
-Filtered and dried -Downstream heated or non-heated bypass air available to ≤1,000°F

Burner EGT
≤1,000° F

Particle Sizing Range
2.5-1,000 nm

Particle Size Distribution Concentration Range
10-107 particles/cm³

Aerosol Particle Size Range
.75-10 nm

Gas Composition Analyzer
CO – CO₂ – O₂

Optic Light Source
300W Xenon Lamp

Optic Video
-32-bit Color -16-bit Monochrome, -Frame rate: 15fps

Optic Detectors
Selection of Various Spectrometers and Photodiodes

NASA’s Glenn Research Center in Cleveland provides ground test facilities to industry, government, and academia. If you are considering testing in one of our facilities or would like further information about a specific facility or capability, please let us know.



Source link

Leave a Comment

Your email address will not be published. Required fields are marked *

Pin It on Pinterest

Verified by MonsterInsights